DZ-Lite c270 Instrument

DZ-Lite™ c270

DZ-Lite c270

  • Compact Size
  • Easy Installation
  • High Throughput
  • User Friendly Interface
  • Innovative Assay Menu
  • Pre-Loaded Parameters
  • Supports 2, 3 & 4 Reagent Assays




 

ASSAY MENU

Catalog No. Assay Method Regulatory Status Throughput Time
to 1st Result
VITAMIN MARKERS
DZ888A-DZL Diazyme EZ Vitamin D Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Cleared 270 tests/hr. Approx. 13 min
DZ689A-DZL Vitamin B12 Assay (Four Vial Liquid Stable)
(Enzyme Immunoassay)
510(k) Cleared 60 tests/hr. Approx. 31 min
DZ690A-DZL Folate Assay (Four Vial Liquid Stable)
(Enzyme Immunoassay)
510(k) Cleared 120 tests/hr. Approx. 30 min
SEPSIS MARKERS
DZ558A-DZL Procalcitonin (PCT) Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Cleared
Health Canada Registered
270 tests/hr. Approx. 13 min
INFLAMMATORY MARKERS
DZ178C-DZL Myeloperoxidase (MPO) Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
USA: For Research Use Only 270 tests/hr. Approx. 13 min
DZ135A-DZL hsCRP Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Cleared 270 tests/hr. Approx. 13 min
CANCER MARKERS
DZ169A-DZL Human Kappa κ Free Light Chain Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Cleared
Health Canada Registered
270 tests/hr. Approx. 13 min
DZ170A-DZL Human Lambda λ Free Light Chain Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Cleared
Health Canada Registered
270 tests/hr. Approx. 13 min
CARDIOVASCULAR MARKERS
DZ568B-DZL Homocysteine Assay (Dual Vial Liquid Stable)
(Enzyme Cycling)
510(k) Cleared
Health Canada Registered
270 tests/hr. Approx. 13 min
DZ10-0148-DZL PLAC® Test for Lp-PLA2 Activity (Dual Vial Liquid Stable)
(Enzymatic)
510(k) Cleared 270 tests/hr. Approx. 13 min
DIABETIC MARKERS
DZ168C-DZL Direct HbA1c Assay (Enzymatic, On-Board Lysis) (Dual Vial Liquid Stable)
(Enzymatic)
510(k) Cleared
Health Canada Registered
60 tests/hr. Approx. 31 min
DZ112B-DZL Glycated Serum Protein (GSP) Assay (Enzymatic) (Dual Vial Liquid Stable)
(Enzymatic)
510(k) Cleared
Health Canada Registered
270 tests/hr. Approx. 13 min
DZ152A-DZL 1,5-Anhydroglucitol (1,5-AG) Assay (Dual Vial Liquid Stable)
(Enzymatic)
USA: For Research Use Only 270 tests/hr. Approx. 13 min
DZ187A-DZL Retinol Binding Protein (RBP) Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
510(k) Exempt 270 tests/hr. Approx. 13 min
DZ188A-DZL Adiponectin Assay (Dual Vial Liquid Stable)
(Immunoturbidimetric)
USA: For Research Use Only 270 tests/hr. Approx. 13 min
 

DZ-Lite™ c270 SPECIFICATIONS

DZ-Lite c270 Main Unit Arrangement

REACTION DESCRIPTION
Optical Measurement Fixed 13 wavelengths
(340 - 800 nm)
Optical Range OD 0 - 3.0
Optical Source Tungsten halogen lamp
Cuvette Washing Auto washing with heated water and 2 kinds of washing solutions
Pure Water Consumption Max: 3.8 L/hour
Reaction Waste Collection Reaction waste stored in a dedicated tank
INTERFACE
LIS Connectivity Bi-directional
Operation Personal Computer
OS Windows 10
Reaction Display Optical absorbance graphic display
Quality Control Views Current, Daily and Cumulative QC. Westgard algorithms
Output Ethernet connection
COMPONENT
Dimension and Weight W800 x D670 x H555 (mm), Weight: Approx. 95 Kg
Power Supply AC 100/115/220/230V, 50/60Hz, Voltage fluctuation less than 10%
Power Consumption 600VA
Waste Liquid Separate drainage (low and high density waste)

DZ-Lite c270 Main Unit Opened